K15 Touchscreen 2 IBP and EtCO2 Patient Monitor
zoom_out_map

K15 Touchscreen 2 IBP and EtCO2 Patient Monitor

N-35310
New product
€3,200.00 Tax excluded
attach_money Offer Your Price
Available

K15 Touchscreen 2 IBP and EtCO2 Patient Monitor

Warranty 1year

Multi-functional patient monitors, designed for monitoring the vital physiological signs of adult, pediatric and neonate patients.

With the functions of real-time recording and displaying parameters, such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows comprehensive analysis of patient's physiological conditions.

 

Worldwide Delivery

 

After Sales Service Guaranteed

 

Secured Payment

K15 Touchscreen 2 IBP and EtCO2  Patient Monitor

Warranty 1 year

Multi-functional patient monitors, designed for monitoring the vital physiological signs of adult, pediatric and neonate patients.

With the functions of real-time recording and displaying parameters, such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it allows comprehensive analysis of patient's physiological conditions.

- ergonomic design with intuitive user interface

- USB socket for data transfer and software upgrade

- 9 traces on-screen waveforms

- Windows style display view, easy to operate

- visual and audible alarm for physiological and technical alarms

- large capacity storage

- suitable for use with original Nellcor sensors

- protection against defibrillator discharge, resistance against the interference from electro-surgical unit; cardiac pacemaker pulse detection and inhibition.

Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.

PC software only GB.

360° degree visible indicator with 3 level alarm.

Lithium battery up to 2.5 hours continuous monitoring.

Standard Accessories:

  • Adult SpO2 probe
  • NIBP adult cuff
  • SpO2 extension cable
  • ECG cable
  • Skin temperature probe
  • Power supply cable
  • Re-chargeable lithium battery
  • Dust-protective cover
  • Disposable electrode
  • Manual: GB, FR, IT, ES, PL, RU
  • 2 IBP module, cable, sensor
N-35310

Specific References

New product

ECG

• Input dynamic range: ±(0.5~5 mVp)

• Differential input impedance: =10 mO

• Bandwidth:

- 0.05~150 Hz (diagnostic)

- 0.5~40 Hz (monitoring)

- 1~20 Hz (operation)

• CMRR:

- =90 db (diagnostic)

- =105 db (monitoring & operation)

• Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto

• Sweeping speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s

• HR measuring range: 15~350 bpm ±1% or ±2 bpm, whichever is greater

• Pacemaker pulse detection and rejection function

RESP

• Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater

TEMP

• Measuring range: 21.0~50.0 °C ±0.2 °C from 25~45 °C

NIBP

• Technique: oscillometric method

• Typical measurement time: <30 seconds (adult cuff)

• NIBP measuring range SYS:

- 40~275 mmHg (Adult)

- 40~200 mmHg (Pediatric)

- 40~135 mmHg (Neonate)

• NIBP measuring range DIA:

- 10~210 mmHg (Adult)

- 10~150 mmHg (Pediatric)

- 10~95 mmHg (Neonate)

• NIBP measuring range MAP:

- 20~230 mmHg (Adult)

- 20~165 mmHg (Pediatric)

- 20~110 mmHg (Neonate)

• NIBP measuring accuracy:

- Mean difference: ±5 mmHg

- Standard deviation: 8 mmHg

• NIBP measurement mode: Manual, Auto, Stat, Multi-cycle mode

• Auto measuring intervals: 1-480 min

SpO2

• Technique: Dual-wavelength optical method

• Measuring range: 0%~100% ±2% for Spo2 range 70~100%

• PR measuring range: 30~250bpm ±2bpm or ±2%, whichever is greater

• Low perfusion performance: as low as 0.3%.

CO2

• Technique: infrared optical method

• Sampling mode: Sidestream or mainstream

• Measuring range: 0~150 mmHg

• Measuring accuracy:

- 0~40 mmHg ±2 mmHg

- 41~70 mmHg ±5% of reading

- 71~100 mmHg ±8% of reading

- 101~150 mmHg ±10% of reading

• Flow rate: 50 ml/min ±10 ml/min (Sidestream)

IBP

• Technique: Strain gauge transducer

• Input sensitivity: 5 µV/V/mmHg

• Measuring range: -50~300 mmHg ±2% or ±4 mmHg, whichever is greater

• Measuring positions: ART, RAP, PA, LAP, CVP, ICP, AUXP1, AUXP2

• Calibration: zero calibrating

Other specifications

• Power supply: AC 100-240 V, 50/60 Hz, 60 VA

• Built-in lithium battery: 11.1V/4400 mah

• Display: 15 inch TFT display

• Alarming method: 3 levels audible-visible alarm

• Networking: Ethernet

• Safety standard: IEC 60601-1

Contact us

optional

Interested in product

Tell us your interest in this product and we will contact you for more details.

K15 Touchscreen 2 IBP and EtCO2 Patient Monitor

K15 Touchscreen 2 IBP and EtCO2 Patient Monitor

Leave us a message
Hello, our team is not online at the moment. We invite you to send us your request via our contact section. It will be processed as soon as possible.