UP-7000 Patient Monitor ECG, SPO2, NIBP, TEMP
UP-7000 Patient Monitor ECG, SPO2, NIBP, TEMP
Warranty 1 year
- 12.1" high resolution colour TFT display with LED backlight
- 3 channel ECG amplification
- arrhythmia analysis and ST segment analysis
- up to 2,000 groups parameter data & 24-hour ECG waveform storage and recall
- 9 trace ECG waveforms simultaneous display
- adult/pediatric/neonate measurement modes
- visual and audible alarms
- built-in rechargeable lithium battery
- built-in thermal printer
- multilanguage internal software: GB, FR, IT, ES, PT, PL, TR, RU, CN
Worldwide Delivery
After Sales Service Guaranteed
Secured Payment
UP-7000 Patient Monitor ECG, SPO2, NIBP, TEMP
Warranty 1 year
- 12.1" high resolution colour TFT display with LED backlight
- 3 channel ECG amplification
- arrhythmia analysis and ST segment analysis
- up to 2,000 groups parameter data & 24-hour ECG waveform storage and recall
- 9 trace ECG waveforms simultaneous display
- adult/pediatric/neonate measurement modes
- visual and audible alarms
- built-in rechargeable lithium battery
- built-in thermal printer
- multilanguage internal software: GB, FR, IT, ES, PT, PL, TR, RU, CN
Standard Accessories:
- Adult SpO2 probe
- NIBP adult cuff
- Temperature probe - skin
- ECG cable 5 leads (RA - LA - LL - PL - C)
- Rechargeable battery
- Printer
- Power supply cable
- Disposable electrode
- Dust-protective mantle
- Manual (GB, IT)
Specific References
NIBP Monitoring - Oscillometric
• Measuring range (Systolic pressure): [Adult: 40~275 mmHg] [Pediatric: 40~200 mmHg] [Neonatal: 40~135 mmHg]
• Measuring range (Diastolic pressure): [Adult: 10~210 mmHg] [Pediatric: 10~150 mmHg] [Neonatal: 20~165 mmHg]
• Measuring range (Mean arterial pressure): [Adult: 40~135 mmHg] [Pediatric: 10~95 mmHg] [Neonatal: 20~110 mmHg]
TEMP Monitoring
• Measuring range: 21.0°C ~ 50.0°C ± 0.2°C
• Responce time: = 150 sec
SpO2 & Pulse Rate Monitoring
• Input dynamic range: 0% ~ 100%
• PR measuring range: 0 bpm ~ 250 bpm
ECG Monitoring
• Input dynamic range: ±0.5 mVp ~ ±5 mVp
• HR measuring range: 15 bpm ~ 350 bpm
RESP Monitoring
• Measuring method: Thorasic impedance
• Monitoring range: 0 rpm ~ 120 rpm, ±5% or ± rpm whichever is greater
Other Technical Specifications
• Power supply: 100 ~ 240 Vac, 50/60Hz
• Power consumption: <80 VA
• Alarming mode: Audible-visual alarm
• Networking port: Ethernet port